WPE DIESEL GENERATORS
Handling of dual voltage type generator
– Operation of change over switch: The AC circuit
breaker on the control panel must be set to 'OFF'
position before running the machine. After starting
the generator, allow the speed to reach rated RPM
and then turn the AC circuit breaker to the "ON"
position, so that the receptical sockets can be used
for operating equipment.
– NEVER try to switch between voltages when the AC
circuit breaker is ON and equipment plugged IN.
– Set the main AC circuit breaker to the "OFF" position
when using the 12v DC power supply.
Check for Airlock
WARNING
The FUEL and engine OIL are drained off by factory
prior to transportation. Generators are dry for
storage.
– Check for airlock in fuel pipeline, and find whether
there is air mixed into the pipeline, if yes, drain away
the air from the pipeline before refuel and start the
diesel engine.
– Fuel filter should be minimum 75% full, if not then air
may be present in system.
– The method to remove is, loosen the 17mm gland
nut connection between injecting pump and high
pressure brass pipeline, put run lever to "RUN"
position and turn over the engine until fuel starts to jet
out.
– Replace and re-tighten 17mm gland and repeat the
process if engine still does not start.
OPERATION
Low oil warning system
– Device works to stop the engine automatically when
the oil pressure falls below the regulatory level and
will prevent engine seizure when the engine oil is
running low or engine pressure is lost.
– The oil temperature will rise high if the engine is
operated with insufficient engine oil. On the other
hand, too much oil is dangerous because the oil may
combust and cause a sudden and excessive rise in
engine rpm, so before operating the machine each
day be sure to check the oil and fill oil to the specified
level if necessary.
Opening the cabinet door and cover.
Opening the cabinet door and raise the door and check
daily.
1. Turn the handle anticlockwise to open cabinet door.
2. Turn the handle clockwise to lock cabinet door.
Break-in operation
While your generator is still new, application of heavy
loads may shorten the life of the engine. Follow the break-
in procedures during the first 20 hours.
1. Avoid applying any heavy load during the break-in
period.
2. Change engine oil regularly. Change the engine oil
every 20 hours or one month after the initial use, and
every 3 months or 100 hours thereafter.
Starting the generator
Electric Start
1. Turn the AC circuit breaker switch to "OFF" position,
Make sure the generator is grounded recommended
200mm earth rod.
2. Turn the starting key to the "Sart" position. (for no
more than 8 seconds).
3. Remove your hand from teh key as soon as teh
engine starts and let the key return automatically to
the initial position.
If the starting motor soesnt start, please wait at least
30 seconds before attempting to start again.
Please Note: If the starting motor is run for too long it
will flatten the battery.
Battery
Check the level of the fluid in the battery once every
month. When the level drops to the lower upper mark
replenish with distilled water up to the upper mark.