Transport And Storage Conditions; Installation; Personnel Requisition - Wilo Yonos MAXO-D Instrucciones De Instalación Y Funcionamiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
en
4.4

Transport and storage conditions

The pump and its packaging must be protected against moisture,
frost and mechanical damage during transport and temporary stor-
age.
WARNING
Risk of injury from sodden packaging!
Packaging that has been sodden loses its strength
and can cause injury to persons if the product falls
out.
WARNING
Risk of injury from ripped plastic strips!
Ripped plastic strips on the packaging render trans-
port protection void. Products falling out may cause
personal injury.
24
ƒ
Only carry by the motor or pump housing ➜ Fig. 4
ƒ
Store in original packaging.
ƒ
Storage of pump featuring horizontal shaft on a horizontal sur-
face. Observe the packaging icon
ƒ
If necessary use hoisting gear with sufficient bearing capacity.
ƒ
Protect against moisture and mechanical load.
ƒ
Permissible temperature range: -20 °C to +70 °C
ƒ
Relative humidity: maximum 95 %
ƒ
Dry pump thoroughly following use (e.g. function test) and
store for a maximum of 6 months.
Domestic hot water circulators:
ƒ
Dirt and contamination should be avoided once the product is
removed from its packaging.
5

Installation

5.1

Personnel requisition

Carry out installation using qualified specialists only.