Service - Mi-T-M Corporation GEN-2000-iMM1 Manual Del Operador

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SERVICE

MAINTENANCE
Ensure that all safety information, warnings, and instructions are read
and understood before any maintenance procedures are performed.
Use service hours or calendar time, WHICH EVER OCCURS FIRST, to
determine the correct maintenance intervals. Stop the engine before
servicing. Put the generator on a level surface and remove the spark
plug cap to prevent the engine from starting. Do not operate the engine
in an unventilated room or other enclosed area.
WHEN REQUIRED:
Fuel Tank Cap and Strainer – Clean
EVERY USE:
Engine Oil Level – Check
Walk-Around Inspection
FIRST 8 SERVICE HOURS OR 1 MONTH:
Engine Oil – Change
EVERY MONTH:
Generator – Inspect
EVERY 25 SERVICE HOURS OR 3 MONTHS:
Engine Oil – Change
Air Filter – Check
EVERY 50 SERVICE HOURS OR 3 MONTHS:
Spark Arrester – Inspect/Clean/Replace
EVERY 100 SERVICE HOURS OR 6 MONTHS:
Spark Plug – Inspect/Adjust/Replace
EVERY 300 SERVICE HOURS OR 1 YEAR:
Cylinder Head – Clean
Engine Valve Lash – Check
EVERY 2 YEARS:
Fuel Line – Check/Replace if necessary
NOTE: Only use genuine parts.