CONTROLS
GENERATOR SWITCH:
Turn the generator switch to the choke position when
starting the engine. Refer to Starting the Engine – Recoil
Start. Turn the generator switch to the on position "I" once
it has been started. To turn off the generator, turn the gen-
erator switch to the off "0" position.
LOW OIL, OUTPUT AND OVERLOAD LAMP:
This generator is equipped with 3 Display LEDs that in-
dicate Low Oil, Overload, and Output Power. The low oil
indicator will illuminate red when there is an insufficient
amount of oil in the crankcase. The overload indicator will
illuminate red when there is a short circuit in a connected
load, or the generator is overloaded. The output power
indicator will illuminate green when the generator is in
normal operation.
PARALLEL CONNECTIONS:)
Two parallel ready generators can be connected together
to increase the total power available to a load by using
the parallel receptacles. The system seamlessly matches
frequency and automatically distributes the load to each
generator so one is not overloaded. Follow the parallel kit
(sold separately) instructions for connection and use of a
parallel kit.
IDLE CONTROL:
This generator is equipped with an idle control switch.
When in the on position "I" the engine will vary speed to
match the required power output to conserve fuel, and
reduce wear and noise.
Note: If loads requiring intermittent power, or multiple
large loads are connected, turn the electronic speed
control switch off "O" to avoid possible engine stall.
To avoid extended warmup time, keep the electronic
speed control off until normal operating temperatures
have been reached.
AC/DC CIRCUIT BREAKERS:
The generator comes equipped with circuit breakers that
protect the unit and the load from short circuit or overload
conditions. If the circuit breaker opens, determine why the
circuit breaker tripped before closing the circuit breaker.
WARNING: DO NOT PUT FOREIGN OBJECTS INTO
THE PLUG RECEPTACLE.
CAUTION: DO NOT PLUG MORE THAN TWO
APPLIANCES INTO THE GENERATOR AT A TIME.
CAUTION: IF CIRCUIT BREAKER CONTINUES TO
TRIP, CHECK APPLIANCE FOR
GENERATOR IS MALFUNCTIONING, SEE YOUR
AUTHORIZED MI-T-M SERVICE CENTER.
14
CONTROLS
DEFECT. IF
1
2
3
Operator's Manual