15. Troubleshooting
The following table shows fault symptoms and describes remedial measures in the event of your machine failing to
work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault
Engine cannot be started
Generator has insufficient or
no voltage
Battery is not charged
28 | GB
Possible cause
Automatic oil shut-off reacts (red LED
No diesel fuel
Mechanical circuit breaker unlocked
Diesel filter blocked
Air filter blocked
Diesel fuel "congealed" due to low outdoor
temperature
Fuse defective
Controller or capacitor defective
Overload protection switch triggered
Air filter dirty.
Fuse defective
www.scheppach.com
Remedy
Check oil level, fill with engine oil
Top up diesel fuel
Slide mechanical circuit breaker to
the right
Clean or replace diesel filter
Clean or replace the air filter
Proceed as described under "Win-
ter operation" section
Change defective fuse
Contact the specialist dealer
Reduce consumption
Clean or replace filter
Change defective fuse