Installation Instructions
230/208 VOLT ELECTRICAL CONNECTION OPTIONS
POWER CORD
CONNECTION
appropriate kit is determined by the voltage, the means
of electrical connection and the amperage of the branch
circuit.
Power supply kit
(
All wiring, including installation of the receptacle,
must be in accordance with the NEC and local codes,
ordinances and regulations. Codes require the use of
an arc fault or leakage current detection device on the
the correct cord for your installation.
Tandem
Perpendicular
Branch Circuit and
Unit Amperage Rating
49-5000355 Rev. 6
Large
Tandem
Proper GE Appliances
Power Cord
with LCDI Device
Power cords may include an arc fault interruption
or a leakage current detection interruption device.
A test and reset button is provided on the plug
case or the inline case. The device should be
tested on a periodic basis by first pressing the
TEST button and then the RESET button. If the
TEST button does not trip or if the RESET button
will not stay engaged, discontinue use of
the Zoneline and contact a qualified service
technician.
ELECTRICAL SUBBASE
CONNECTION
Branch Circuit and
Unit Amperage Rating
Electrical subbases provide an enclosure for direct
includes the power cord.
the installer to ensure the connection of components
is done in accordance with these instructions and all
electrical codes.
When using a sub-base electrical connection, the
RAK4002D Junction Box is required for a complete
and proper installation.

DIRECT CONNECTION

Branch Circuit and
Unit Amperage Rating
Review installation instructions provided with direct
connect kits for detailed assembly instructions.
When using a direct connection, the RAK4002D
Junction Box is required for a complete and proper
installation.
Proper GE Appliances
Subbase Kit
Power Supply Kit