TECHNICAL SPECIFICATION
Model
Capacity
Energy Class (ERP)
COP (ERP)
Duct air flow (nom.)
Rated power input
Current (nom.)
Current (Rated.)
Power supply
Max outlet water
temperature (with-
out using E-heater)
Refrigerant
Rated water yield
Max. Water operat-
ing pressure
Rated water pressure
Set point relief valve
Sound power level
Net weight
Net size(WxHxD)
Package Size
(WxHxD)
* Capacity and power input based on the following conditions: Ambient temperature 20°C,
water temperature from 10°C to 55°C.
**Related to the supplementary heater
*** Water heating energy efficiency based on standard ERP, M cycle: Ambient temperature14°C
/13°C, water temperature from 10°C to 55°C.
E110WHM
kW
0.85* (+1.5**)
m³/h
W
250 (+1500**)
A
1.16* (+6.5**)
A
1.81(+6.5**)
V/Ph/H
220-240~/1/50
z
°C
R134a/650
.../g
L/H
Mpa
Mpa
Mpa
dB (A)
φ520x1368
kg
mm
mm
580x580x1515
A+***
2.80***
300
60
18.5
1.0
0.6
0.7
46
59.5
29
E150WHM
0.85* (+1.5**)
A+***
2.80***
300
250 (+1500**)
1.16* (+6.5**)
1.81(+6.5**)
220-240~/1/50
60
R134a/650
18.5
1.0
0.6
0.7
46
φ560x1475
57.5
610x580x1610
V.1