Installation Overview - EAS ELECTRIC ThermoHome Serie Manual De Instrucciones

Ocultar thumbs Ver también para ThermoHome Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

-
If the unit connects with air ducts it should be DN 120mm for pipes or 120mm in-
ternal diameter flexible hose. Total length of the ducts should not be longer than
8m or the maximum static pressure should not exceed than 60Pa. Be in mind of
bending site of the duct no more than 4m.

Installation overview

water outlet 2
water outlet 1
tap water
Note: Solar heat exchange coil is optional.
ATTENTION:
The one-way safety valve must be installed.
-
unit, or even hurt people. The set point of this safety valve is 0.7 MPa. For the instal-
lation place please refer to the pipeline connection sketch.
-
The discharge pipe connected to the one-way safety valve is to be installed in a
continuously downward direction and in a frost-free environment.
-
The water may drip from the discharge pipe of the one-way safety valve and that
this pipe must be left open to the atmosphere.
mixing valve
hot water outlet
mixing valve
manual valve
manual valve
one way safety valve
manual valve
filter
cold water inlet
condenser water outlet
manual valve
If not, it could cause damage to the
14
V.1
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Thermohome e110whm

Tabla de contenido