Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
EN
If the maximum pressure is not indicated on the product (e.g. mattress), control the hardness of the product during infl ation by
pressing it with your hand.
Never leave the product unattended during infl ating.
The compressor is designed for short period use (maximum 10 minutes). Operating the compressor for a long time will cause the
device to overheat and damage it.
Reduced effi ciency or heating of the hose connection to the housing means that the device has been operating too long and is
overheating. When this occurs, turn the device off immediately and allow it to cool for at least 30 minutes before restarting.

PRODUCT OPERATION

If the product to be infl ated is equipped with a valve such as in car tyres, it is not necessary to install any adapter. If the valve is of
a diff erent type, one of the supplied adapters must be installed.
The hose is equipped with a clamped connection. The connection lever should be aligned with the connection and then put the
connection on the valve or adapter and rotate the connection lever so that it is perpendicular to the connection (II). This will clamp
the connection on the valve or adapter.
Place the compressor on a fl at, level and hard surface. Do not hold the compressor in your hands during operation.
Connect the compressor to the power supply by inserting it into the socket of the car's electrical system.
Press the power switch, the display will light up. Select the pressure unit using the button marked with the letter "R". The following
pressure units are available: bar, psi (pound per square inch) and kg/cm
2
. Pressing this button again will change the unit and the
symbol of the selected unit will be shown on the display.
Set the target pressure using the buttons marked "+" and "-". When the desired pressure is reached, the pumping process will
be completed automatically. The "+" button increases the setting and the "-" button decreases the setting. The selected setting
indicator will fl ash three times on the display and then the display will show 0.
Connect the hose end to the valve of the product to be infl ated and press the power switch to begin infl ating. Infl ating will stop
automatically after the previously set pressure has been reached. The infl ation process can also be interrupted at any time by
pressing the power switch.
When the infl ating is fi nished, turn off the compressor with the power switch, disconnect the compressor from the power supply
and then from the infl ated product.
Next, proceed with maintenance.
Plug fuse replacement
If the plug of the power cord is equipped with a ring (III), it means that there is a fuse with parameters of 10A/250V inside it.
Unscrew the ring and replace the fuse with a new one each time the compressor stops turning on when the power switch is set
to the "on" position.
Lamp operation
The compressor is equipped with a lamp which is turned on with a separate power switch. Since the product is not equipped with a
battery, the use of the lamp is only possible after connecting the compressor to the power supply. Successive presses of the power
switch activate successive light modes: continuous, SOS signal using the Morse code, fl ashing, lamp switched off .
MAINTENANCE, TRANSPORT AND STORAGE
The product does not require any special maintenance. After you have fi nished using the product, clean its housing with a slightly
damp cloth, then dry or leave to dry. Never immerse the product in water or any other liquid. Do not use alcohol, acids, caustics
or abrasives for cleaning the product.
When carrying the product always hold it by the handle or if it is missing, by the housing. Never carry the product grasping the hose
and/or the power cord. Always carry the product disconnected from the power supply. The plug or clamps must be disconnected
from the power supply.
It is recommended to store and transport the product in the packaging it was delivered in or other packaging protecting it from
moisture and dust. The temperature in the place of storage must be within the range of 0°C – 40°C, and the relative humidity RH
must be <85% without condensation.
O R I G I N A L
I N S T R U C T I O N S
9
Tabla de contenido
loading

Tabla de contenido