Wiha 45215 Manual De Instrucciones página 35

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 71
Capacity test
Frequency
Temperature
measurement
Data HOLD
RELATIVE value
measurement
MIN/MAX
measurement
Auto/Manual RANGE
selection
DMM battery LOW
indication
NCV measurement
(Non-contact AC
electric field detection)
True RMS
Backlight
Display
IP rating
Battery
Fuse
Standards
Overvoltage category
Pollution degree
Operating temperature
Storage temperatur
Note: The lowest ranges are specified from 5 % of the range.
Note: AC Voltage and AC Current ranges are specified up to 400 Hz.
As the frequency increases (over 400 Hz), the accuracy deteriorates.
Measuring
Resolution
range
6.000 nF
0.001 nF
60.00 nF
0.01 nF
600.0 nF
0.1 nF
6.000 μF
1 nF
60.00 μF
10 nF
600.0 μF
100 nF
6.000 mF
1 μF
60.00 mF
10 μF
600.0 Hz
0.1 Hz
6.000 kHz
1 Hz
60.00 kHz
10 Hz
600.0 kHz
100 Hz
6.000 MHz
1 kHz
60.00 MHz
10 kHz
-200...1.350 °C
yes
yes
yes
yes
yes
yes
yes
yes
6.000 counts, bargraph
IP40
AAA 2x 1.5 V; R03
Ceramic fuses; F 600 mA/1,000 V and F 10 A/1,000 V
EN 61010-1, EN 61010-02-033, EN 61010-031,
EN 61326
CAT IV/600 V; CAT III/1,000 V
2
0...50 °C
-10...60 °C
EN
Accuracy
±(10 % of m.v. + 25D)
±(2 % of m.v. + 10D)
±(1.5 % of m.v. + 5D)
±(1.5 % of m.v. + 5D)
±(1.5 % of m.v. + 5D)
±(2 % of m.v. + 10D)
±(10 % of m.v. + 25D)
±(10 % of m.v. + 25D)
±0.1 % + 1D
±(10 % of m.v. + 1D)
35