4. Do not store your laser in the kit box if the laser is wet. Dry exte-
rior parts with a soft, dry cloth and allow the laser to air dry.
5. Do not store your laser at temperatures below 0˚F (-18˚C) or
above 105˚F (41˚C).
CLEANING
Exterior plastic parts may be cleaned with a damp cloth and mild
detergent. Although these parts are highly solvent resistant,
NEVER use solvents. Never use compressed air to clean the laser.
Field Calibration Check
Field calibration checks should be done frequently. This section
provides instructions for performing simple field calibration checks
of your D
WALT Rotary Laser. Field calibration checks do not cali-
E
brate the laser. That is, these checks do not correct errors in the
leveling or plumbing capability of the laser. Instead, the checks indi-
cate whether or not the laser is providing a correct level and plumb
line. These checks cannot take the place of professional calibration
performed by a D
WALT service center.
E
LEVEL CALIBRATION CHECK
1. Set up a tripod 50' (15m) from a vertical wall as shown. Make
sure the head of the tripod is level using a bubble level.
2. Mount your rotary laser on the tripod so that the X-axis points
toward the wall as shown.
3. Turn the laser on, but do not put the laser in rotation mode.
4. Manually point the dot at the far wall. Mark the center of the dot
elevation on the wall.
NOTE: pointing the dot on a white surface makes marking easier.
5. Turn the entire unit 180˚ so that the X-axis points away from the
wall. Manually rotate the laser dot (or use the right /left arrows
on the remote control) so it is as close as possilbe to the first ele-
vation mark. Again, mark the center of the dot on the wall.
6. If the distance between the two marks is no more than 1/8" (3.2
mm), the laser is properly calibrated.
7. Repeat the above steps for the Y-axis by pointing the Y-axis
towards the wall and then turning the laser 180˚ again.
PLUMB ERROR CHECK
1. Using a standard plumb bob as a reference, mark the top and
bottom of a wall (Be sure to mark the wall and not the floor &
ceiling.)
2. Position the rotary laser securely on the floor approximately 3'
(1m) from the wall. The closer to the wall, the more accurate this
check will be.
3. Turn the laser on, and point the dot at the mark on the bottom of
the wall. Then, using the up/down arrows on the remote control,
rotate the dot upwards. If the center of the dot scans over the
mark on the top of the wall, the laser is properly calibrated.
NOTE: This check should be done with a wall no shorter than the
tallest wall for which this laser will be used.
Repairs
To assure product SAFETY and RELIABILITY, repairs, mainte-
nance and adjustment should be performed by certified service
centers or other qualified service organizations, always using iden-
tical replacement parts.
Full One Year Warranty
D
WALT heavy duty industrial tools are warranted for one year from
E
date of purchase. We will repair, without charge, any defects due to
faulty materials or workmanship. For warranty repair information,
call 1-800-4-D
WALT. This warranty does not apply to accessories
E
or damage caused where repairs have been made or attempted by
others. This warranty gives you specific legal rights and you may
have other rights which vary in certain states or provinces.