GB
MT
not carry out conversion work on the
equipment.
•
Please read the notes in the operating
instructions on the topic of "mainte-
nance and cleaning". Any measures
above and beyond these, particularly
opening the equipment, are to be car-
ried out by an electrician. In the case
of repairs, always contact our service
centre.
Electrical safety:
Caution: to avoid accidents and in-
juries from electric shocks:
•
After erection, the mains plug must be
freely accessible when the equipment
is in operation.
•
Before operating your new pump, have
a specialist check:
-
The earthing, the protective multiple
earthing; the residual current circuit
breaking must be compliant with the
safety regulations of the energy sup-
ply company and function without
fault,
-
The protection of the electrical plug
connections from the wet.
-
If there is a risk of flooding, fix the
plug connections in an area that is
safe from flooding.
•
Ensure that the mains voltage match-
es the specifications on the rating
plate.
•
The electrical installation shall be ac-
cording to national wiring rules.
•
Connect the equipment only to a
socket with a residual current protec-
tion device (residual current circuit
breaker) with a rated current of not
more than 30 mA; minimum fuse 6
amperes.
•
Before each use, check the equip-
34
All manuals and user guides at all-guides.com
ment, cable and plug for damage. De-
fective cables are not to be repaired,
but rather replaced by new ones.
Have any damage to your equipment
repaired by a specialist.
•
If the power cable for this equipment
is damaged, it must be replaced by
the manufacturer, a customer ser-
vice agent of the same or a similarly
qualified person in order to prevent
hazards.
•
Do not pull the plug from the socket
by the cable. Protect the cable from
heat, oil and sharp edges.
•
Do not carry or fix the equipment by
the cable.
•
Use only extension cables that are
protected from spray water and de-
signed for outdoor use. Always fully
unroll a cable drum before use. Check
the cable for damage.
•
Before any work on the equipment,
during work breaks and in the case
of non-use, remove the plug from the
socket.
•
The cross-section of mains connec-
tion lines must be no smaller than
rubber hose lines with the designation
H07RN-F. The line must be 10 m long.
Areas of Application
The foul water submersible pump is a
drainage pump and designed for trans-
porting water and sewage water (max.
particle size 35 mm) up to a temperature
of max. 35°C.
It may be used e.g. domestically, in horti-
culture, in agriculture and in the sanitary
industry. It is suitable e.g. for pumping
around and pumping out tanks and con-
tainers, for pumping out flooded cellars
and for removing water from fountains
and drains.