OPERATING INSTRUCTIONS
3.2
Operating elements and status indicators
en
4
Mounting
20
O P E R A T I N G I N S T R U C T I O N S | CMB
CMB18
1
2
1
Potentiometer: sensitivity adjustment
2
Yellow LED: digital output
3
Green LED: Stable ON/OFF state
Table 1: Description of the LEDs
Green LED
Yellow LED
O
o
o
o
o
O
O
O
1
Only SIO (standard I/O mode)-relevant displays are shown.
Mount the sensor on suitable brackets. Recommended mounting accessories can be
found in the product data sheets or at www.sick.com.
The tightening torque is:
•
CMB18: ≤ 2.6 Nm
•
CMB30: ≤ 7.5 Nm
Observe application conditions such as sensing range, mutual interference and installa‐
tion instructions.
NOTE
The maximum sensing range or sensitivity can be achieved by earthing the sensor
housing and the detection object.
Application conditions
Sensing range:
Table 2: Sensing range
CMB18-08B
CMB18-12N
CMB30-16B
CMB30-25N
3
2
1
Sensor in stable OFF state
Output is deactivated (OFF), No object detected
Output is activated (ON), Object detected
Output is activated (ON), Sensor in stable ON state
CMB30
1
3
Max. S
[mm]
n
8
12
16
25
8027571/2022-03-07 | SICK