TECshow GOBO DERBY UV Manual De Usuario página 7

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

10
Test
11
DISP
12
Fhrs
13
Ver
14
Rset
Remarks: DMX signal takes priority to operate, no matter what mode the light is now, after connecting to
DMX controller, the light will enter into DMX mode as master unit, and other units will be slave units automat-
ically. After finishing menu setting, press MENU and hold it for a long time to enter the work mode we already
set, or await 10seconds to enter the work mode we already set.
6. DMX CHANNEL
8 CH
CH 1
Control mode
CH 2
Spot LED color control
CH 3
Spot LED strobe control
CH 4
Spot LED control
CH 5
White LED dimmer
CH 6
White LED strobe
V10
DMX value
0-9
10-69
70-129
130-179
180-255
0-9
10--198
199-225
226-255
0-9
10-244
245-255
0-127
128-255
0-255
0-244
245-255
Test light function
LED display reverse
Total working time
Software version
Light reset
Function
No function
Show 1: spot LED show
Show 2: white LED show
Show 3: UV LED show
Show 4: all shows by random
Spot LED OFF
Color choose (15 options, 13 value for each
option)
Color flowing 1 (single color) slow to fast
Color flowing 2 (several colors) slow to fast
Spot LED strobe OFF
Spot LED strobe speed (slow to fast)
Spot LED strobe with sound control
Spot position choose
Spot scanning (slow to fast)
white LED dimmer
white LED strobe speed (slow to fast)
white LED strobe with sound control
English version
P. 7
| Tecshow Gobo Dervy UV
Tabla de contenido
loading

Tabla de contenido