8.2. TRANSFORMATION RATIO
CONFIGURATION.
To configure the transformation ratio of the CT, follow these steps
on the inverter display:
Main configuration
•
CT Ratio:Set the value 2000:1 for the CT supplied with the
•
inverter.
8.3. ZERO INJECTION FUNCTION.
The "Zero injection" function prevents the energy generated by
the inverter that is not consumed in the same installation from
being fed into the grid. In other words, it reduces the power of the
inverter so that the generation is adapted to the consumption.
To activate the function, follow these steps on the inverter display:
Main configuration
•
Power limit – make sure that it is set to "ON".
•
Export.
•
Change from 100% to 0%.
•
Once the "Zero injection" is configured, the inverter will limit its
power to match it at all times to the consumption of the installation
and not inject excess energy into the grid.
The transformer CT must be installed and connected,
as described in section 6.5.3.
8.4. ON-LINE MONITORING
OF THE INSTALLATION.
The EQX2 inverter provides a monitoring port that can gather and
transmit data from the inverter to the monitoring platform through
an external monitoring device.
There are two methods available, via download and registration
of the application (Fig. 39) and through the Configuration of the
installation (plant) in the EQX-sun application (Fig. 40).
If there are download problems, contact your distributor or
SALICRU´s technical support.
8.4.1. Download and register the "EQX-sun" app.
Download the EQX-sun app and install it on the smartphone or
tablet of the end user of the EQUINOX solar inverter.
64
This process can take a few min-
utes. Once complete, open the
EQX-sun app.
A home screen will appear to enter
the credentials if you are already
a user or to register a new user:
Fig. 39. Application home screen.
To register a new user, click above the text
1
"Register" so that the application allows you to complete
the necessary fields to process the registration and be
able to use the application.
A demo version of the application is available.
To open it, press the "Demo" button on the
bottom right of the screen.
2
1
3
SALICRU