Specification; Front View; Top View; Side View - Furrion FCR16DCASA-BG Manual De Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Specification

E
H
G

Top View

A

Front View

Dimension
3215/16"
A
836 mm
251/16"
B
636 mm
701/16"
C
1780 mm
59"
D
1498 mm
NOTE:
● The product must be correctly installed, located and
operated in accordance with the instructions contained in
the User Manual provided.
● Parameters provided in table are design parameters.
Because of the various reasons, there will be a slight
deviation between actual dimension and design
parameter. The data listed are only for reference.
CCD-0005509 Rev: 03-08-22
D
A
B
C
C

Side View

129/16"
E
319 mm
F
343 mm
403/16"
G
1020 mm
2113/16"
H
554 mm

Site Preparation

Select Location
● Your new refrigerator must stand on a flat surface which
should support a weight of 529Lbs (240kg). Surface must
F
be level relative to the coach floor plane.
NOTE: A slope that is comfortable to live with, and from
normal transportation is acceptable.
● If the appliance is to be placed onto the carpet, support it
with a wooden board. Do not place the appliance directly
on the carpet, as the heat from the compressor may
cause the carpet to fade.
● For best and most efficient operation, the refrigerator
should operate within 50°F ~ 109°F (10°C ~ 43°C). If
installing near large heat sources, such as furnaces,
fireplaces, furnaces, etc. Ensure a thermal barrier, such as
wood paneling, isolates the refrigerator space as not to
hinder performance of the appliance.
Refrigerator Cabinet/Enclosure Preparation
● Position the appliance away from sources of heat such as
stoves, radiators, direct sunlight, direct weather such as
rain, etc.
Min. cabinet dimension
D
Electrical Connection
Any electrical work required to install this appliance should
be carried out by a qualified or competent person.
All Furrion products referenced in this manual is to be
13½"
installed in accordance with local and national codes,
including the latest editions of the following standards:
USA:
− NFPA 1192
− NFPA 70
− ANSI/RVIA low Voltage
Canada:
− C22.1
− CSA Z240
The appliance is powered by Nominal DC 12V and must be
supplied at SAFETY EXTRA-LOW VOLTAGE circuit, a listed
power converter that conforms to UL 458 and/or C22.2 No.
107.1 is required.
- 5 -
W
H
H
D
NOTE: Dimensions
W
include the required
clearance for venting.
WARNING
Min. 337/8'' (861 mm)
Min. 711/16'' (1805 mm)
Min. 2413/16'' (630 mm)
Tabla de contenido
loading

Este manual también es adecuado para:

Fcr16dcasa-ss20211238152021123827

Tabla de contenido