Alarm Signals - klover DEA ECO 6 Instrucciones De Uso

Ocultar thumbs Ver también para DEA ECO 6:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
CS.SE.IST-1 / Rev 1.0
If the outage lasts longer than Pr48, when power is restored, the appliance will enter the "STAND-BY CLE" (stand-by) mode running the entire switch-
off and cleaning cycle until cooling. When this phase is over, the appliance can be restarted resuming work at the set power.
Previous state
OFF
CHECK UP
PELLET LOADING
FLAME STAND-BY
FLAME STAND-BY / PELLET
LOADING
STABILISATION
STABILISATION
WORK (any phase)
WORK (any phase)
BRAZIER CLEANING
BRAZIER CLEANING
SWITCHING OFF
STAND-BY

Alarm signals

The following table describes the different alarms which may appear.
DISPLAY VISUALISATION
AL 01 – BLACK OUT
AL 02 – TEMP. F.GAS
AL 03 – REG. ENCODER
AL 04 – NO ENCODER
AL 05 – IGNIT. FAILED
AL 06 – PELLET CHECK
AL 07 – THERM. SAFETY
AL 08 – DEPRESS.-FAILURE
AL 10 – SCREW FEED SAFETY
Every alarm causes the appliance to switch-off immediately. The alarm state is reached after the time set on Pr11
reset by pressing button 4 for a while. In the event of a fault, contact the Klover Authorised technical assistance centre.
Black-out duration
any
OFF
any
CHECK UP
any
BLACK OUT ALARM
any
BLACK OUT ALARM
any
BLACK OUT ALARM
Duration < Pr48
STABILISATION
Duration > Pr48
STAND-BY CLE with automatic re-ignition after machine cooling
Duration < Pr48
WORK (any phase)
Duration > Pr48
STAND-BY CLE with automatic re-ignition after machine cooling
Duration < Pr48
BRAZIER CLEANING
Duration > Pr48
STAND-BY CLE with automatic re-ignition after machine cooling
any
SWITCHING OFF and after cooling OFF
any
STAND-BY
Black-out alarm. When power is cut off under determined conditions
Faulty or disconnected flue gas temperature sensor.
This occurs when the speed detected by the flue gas extractor does not correspond with the set
speed.
Flue gas extractor or flue gas extractor encoder faulty. This occurs when the encoder (tachometer)
in the extractor detects an extractor speed equal to 0.
No ignition. This occurs when the minimum temperature in the combustion chamber (Pr13) is not
reached within the maximum ignition cycle time (Pr01).
Sudden shut-down during the work phase. This occurs when, during the work phase, the
temperature in the combustion chamber drops below the minimum threshold (Pr13).
Temperature safety device. This occurs when the safety thermostat (pellet container over
temperature) or the fire door open or not correctly closed cuts in. If the safety thermostat cuts in the
appliance must be manually rearmed (see"Components of the appliance").
Poor depression. This occurs when the flue gas pressure switch cuts in due to poor draught in the
flue pipe or the pellet container door is open.
This occurs when a continuous loading of pellets takes place (the screw feed gear motor does not
stop for at least 0.2 seconds during the maximum work interval of 6.0 seconds). Before the alarm
is activated a safety relay cuts in and forcibly cuts off the power supply to the gear motor.
State after power restore
ORIGIN OF ALARM
17
ENGLISH
(see"What happens if...")
(set as default at 90")
and it can be