8
Operator Control Panel (continued)

Sanitizer Output LED Indicators

The five (5) LED indicators display as a bar graph to show the cell output in either 2% or 20% increments, the
percentage of the total output capacity of chlorine being produced. Percentages from 2% to 10% are
represented by blinking LEDs. Percentages from 20% to 100% are represented by solid LEDs. In BOOST
mode, these LEDs scroll from left to right.
0%
No LEDs lit - No chlorine produced - IntelliChlor SCG is off.
2%
1 LED blinking
4%
2 LEDs blinking
6%
3 LEDs blinking
8%
4 LEDs blinking
10%
5 LEDs blinking
20%
1 LED solid
40%
2 LEDs solid
60%
3 LEDs solid
80%
4 LEDs solid
100%
5 LEDs solid

More and Less Output Buttons

The More and Less buttons control the percentage of the total output capacity that the IntelliChlor SCG is
producing while the pump is on (see Sanitizer Output LED indicators above).The lights act as a bar graph: the
more lights that are on, the more chlorine is produced. Blinking LEDs represent 2%, 4%, 6%, 8% & 10% while
solid LEDs represent 20%, 40%, 60%, 80% and 100%.Slide the panel cover up to access the More, Less and
Boost On/Off buttons. Note: When an IntelliChlor is connected to an IntelliTouch
Control System, the Less and More buttons are disabled and IntelliChlor SCG Sanitizer Output is controlled
externally.
More: Increases the output of the cell in 2% increments up to 10% and then 20% increments. Example: The
Sanitizer Output display is showing 8%. Pressing the MORE button once will blink the 10% light. The unit will
produce chlorine at 10% of total capacity. Pressing MORE again will turn on the 20% light, and so on until all
five (5) lights are on solid.
Less: Decreases the time the cell produces chlorine, in either 2% or 20% increments (from 20% to 100%).
Example: The Sanitizer Output display is showing 40%. Pressing the LESS button once will turn off the 40%
light, leaving only the 20% light. The unit will produce 20% of total capacity of the cell. Pressing LESS again
will turn go to 10% (all 5 LEDs blinking).
Boost On/Off: Press both the More and Less buttons together to turn Boost mode on or off. Boost mode sets
the sanitizer output to run 100% for the next 24 hours of pool pump run time. If the time clock switches off the
pump cycle, then switches power back on the next day, Boost mode will continue until 24 hours has elapsed
since Boost mode was turned on or Boost mode is canceled by the user. The Sanitizer Output display will scroll
the output LEDs to indicate Boost mode.

Self-Cleaning

The self-cleaning feature reduces scale buildup on the blades of the IntelliChlor SCG. The self-cleaning cycle
tends to reduce the life of the IntelliChlor SCG, therefore, it should be used only to the extent necessary to
minimize the scale buildup on the blades. It is factory set to two (2) hours for the first 30 days of operation,
then automatically switches to three (3) hours.
®
IntelliChlor
Salt Chlorine Generator Installation and User's Guide
Produces chlorine for 64 seconds of every hour.
Produces chlorine for 127 seconds of every hour.
Produces chlorine for 16 seconds of each 5 minute period.
Produces chlorine for 21 seconds of each 5 minute period.
Produces chlorine for 27 seconds of each 5 minute period.
Produces chlorine for 53 seconds of each 5 minute period.
Produces chlorine for 106 seconds of each 5 minute period.
Produces chlorine for 159 seconds of each 5 minute period.
Produces chlorine for 212 seconds of each 5 minute period.
Produces chlorine for 265 seconds of each 5 minute period.
®
®