Intellichlor "Dummy" Cell; Selecting Model Size - Intellichlor Model Ic20, Ic40, Ic60; Installing The Intellichlor Cell Assembly - Pentair INTELLICHLOR IC15 Guía De Instalación Y Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

22
®
IntelliChlor
SCG "Dummy" Cell
After new pool construction has been completed, in order to prevent debris from entering the IntelliChlor SCG,
it is recommended that the IntelliChlor SCG "pass-through" cell (P/N 520588) be installed before installing the
IntelliChlor SCG. After the pool system has flushed the debris from the pipes, remove the "dummy cell" and
install the IntelliChlor SCG.
Selecting Model Size (see chart on page 1)
Installing the IntelliChlor SCG Cell Assembly
Install the IntelliChlor cell assembly no closer than three (3) feet away from the heater outlet, if used. For
more information see plumbing diagrams on page 4 and 5.
Note: For best flow sensing, provide at least 12"-18" of straight pipe in front of the cell inlet.
Note: After new pool construction has been completed, in order to prevent debris from entering the
IntelliChlor cell assembly, it is recommended that the IntelliChlor SCG pass-through cell (P/N 520588) be
installed before installing the IntelliChlor SCG cell. After the pool system has flushed the debris from the
pipes, remove the pass-through cell and install the IntelliChlor cell.
Note: Pipe couplings: Schedule 80, maximum pressure 75 psi at 70° F (21° C)
To install the IntelliChlor
1. Using PVC glue, mount the PVC couplings to the plumbing pipe. Allow the glue to dry.
2. Mount the cell vertically. Allow access to the cell operator control panel. Install the cell onto the
couplings. Ensure the O-rings are seated properly.
3. Switch on the pump and visually inspect for leaks around the couplings.
Cell Union Coupling with
o-ring (2x)
Water flow out
®
IntelliChlor
Salt Chlorine Generator Installation and User's Guide
®
SCG Cell:
Cell Union Coupling with
o-ring (2x)
Water flow in
Tabla de contenido
loading

Este manual también es adecuado para:

Intellichlor ic20Intellichlor ic40Intellichlor ic60

Tabla de contenido