gs yuasa yuasa YCXL12 Guia Del Usuario página 9

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
1) Activation – Wakes up the lithium battery BMS to detect battery Voltage to enable
the charger to start charging
2) Soft start – Increases your battery life by gently starting to charge the battery until
the battery reaches a set Voltage.
3) Bulk charge – Reduces charging time by delivering maximum charge until the
battery reaches a set Voltage.
4) Absorption 1 – Uses constant Voltage and ensures the battery receives charge
without overcharging the battery.
5) Absorption 2 – Steps up the constant Voltage and ensures the battery receives a
full charge without overcharging the battery.
6) Full – Battery is 100% charged and the charger output will switch off.
7) Analysis – The charger will monitor the battery Voltage and will restart when
required.
LED warning indicators
Fault LED
Combine LED bar
On
On
On
Flashing
Flashing
Flashing
Fast
flashing
Blinking
Flashing
Blinking in sequence
Flashing
Flashing
Flashing
Descriptions
Output short circuit or reverse polarity
Battery faulty or seriously sulphated
(less than 11.8V)
Battery rejuvenation failed
Soft start phase failed
Bulk charge phase (Less than 13V)
failed
Bulk charge phase (Above 13V) failed
Battery charger is overheating.
Unplug and allow for the temperature
to cool down
Power supply mode is overloaded.
The battery is below 9V
9
Tabla de contenido
loading

Productos relacionados para gs yuasa yuasa YCXL12

Tabla de contenido