Technical data
11
Technical data
11.1
General
Max. managed charging stations:
●
●
Max. number of zones:
Connection protocol:
OCCP backend:
11.2
Power supply
Embedded PC
Power supply:
Power:
Power adapter
Power supply:
Output voltage:
Output cable:
Overvoltage category:
Protection class:
11.3
Ambient conditions
Use:
Access limitations at set-up location:
Installation (stationary):
Operating temperature:
Storage temperature:
Relative humidity:
Altitude:
11.4
Interfaces Embedded PC
Ethernet interface
Quantity:
Data transfer rate:
296
medium
large
40
200
15
Modbus TCP
Configurable (1.5 / 1.6)
9 - 36 VDC
Max. 30 W
100 - 240 VAC (50/60 Hz)
24 VDC
Max. 60 W
II in accordance with EN 60664
II
Indoor
Limited access (control cabinet)
Embedded PC: On the wall or on a top hat
rail
Power adapter: Only on a top hat rail
-20 °C to +55 °C
-40 °C to +85 °C
5% to 95% (non condensing)
max. 3.000 m above sea level
1 (RJ45)
10/100/1000 Mbit/s
Configuration manual V1.01
M20
© KEBA 2022