A configuration file without a serial number in the filename can be used for
the configuration of multiple charging stations. If the configuration is only
valid for exactly one charging station, the filename must include the serial
number of the desired charging station.
Adapting the content
The specific configurations that only apply to one charging station must be
adapted or deleted in the configuration file.
All settings are listed in the configuration file. The individual sections are
marked with [Name]. The name of the parameter (designation) is to the left
of the equal sign ("="). The value is located to the right.
To adapt and delete the specific configurations, proceed as follows:
1) Open the configuration file with a text editor
2) Change the following entries:
3) Delete the following entries completely:
4) Save the file
Information
By deleting all
tomatically searches for other charging stations in the charging network.
The number of charging stations specified under
number searched for.
Adapting the configuration (optional)
The configuration may need to be adapted manually. Each of the settings
listed can be adapted by editing the value to the right of the equal sign "=".
Example of a possible adaptation to the configuration
AuthorizationEnabled=
Information
Invalid settings are not applied.
Configuration manual V1.01
© KEBA 2022
AmountConnectors=[x]
The number of charging stations in the charging network must be
adapted here.
ChargeBoxIdentity=[xxx]
Connect2ConnectorSerial[x]=[xxx]
HOTSPOT_SSID=[xxx]
HOTSPOT_KEY=[xxx]
Connect2ConnectorSerial
Original configuration
entries, the charging station au-
Adapted configuration
true
AuthorizationEnabled=
Configuration
is the
AmountConnectors
false
277