KENMORE ELITE 796.8099 Serie Guia De Uso Y Cuidado E Instrucciones De Instalacion página 24

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

THE LCD DISPLAY (cont.)
9
FLOW SENSE™ DUCT BLOCkAGE SENSING
SYSTEm INDICATOR
The FLOW SENSE™ duct blockage sensing system
detects and alerts you to blockages in the ductwork
that reduce exhaust flow from the dryer. This
improves operating efficiency and helps minimize
service calls, saving you money.
If no bars are shown in the display, the
ductwork is free from blockages.
If two bars in the display are lighted,
examine the dryer exhaust system for lint
build up or other restrictions, including
damage, excess length, foreign objects,
etc. See note below.
If all bars are lit, the dryer ductwork has
a blockage that needs to be removed
immediately.
NOTE: If the duct has been checked and cleaned
and two bars are still displayed after several cycles,
then there is some restriction in the duct due to
length, condition, etc. In this case, no further action
is necessary and the dryer can be used normally.
However, drying times may be increased and there
may be some reduction in operating efficiency
All manuals and user guides at all-guides.com
HOW TO USE
24
• 2 bars are displayed In the LCD screen.
END OF CYCLE
1. Possible causes
• Ductwork is slightly too long or has too many turns/
restrictions.
• Partial blockage of the ductwork due to lint buildup.
2. Solutions
• I nstall a shorter or straighter duct run. See the
Installation Instructions.
• D uctwork should be checked/cleaned soon.
Dryer can be used in this condition, but drying
times may be longer.
• If "END OF CYCLE" is displayed after the end of
cycle, it will be off in 4 minutes. If POWER button
is pressed or the door is opened, power will be off
immediately.
• 4 bars are displayed In the LCD screen.
NEED FLOW CHECK
1. Possible causes
• Ductwork is too long or has too many turns/
restrictions.
• Significant blockage of the ductwork due to lint
buildup or debris.
2. Solutions
• Install a shorter or straighter duct run. See the
Installation Instructions.
• D uctwork should be checked/cleaned soon.
Dryer can be used in this condition, but drying times
may be longer.
• I f "NEED FLOW CHECK" is displayed after the end
of cycle, it will be off in 2 hours. If POWER button
is pressed or the door is opened, power will be off
immediately.
THE DUCTWORK HAS
A BLOCKAGE THAT NEEDS
TO BE REMOVED
IMMEDIATELY.
Tabla de contenido
loading

Tabla de contenido