This function only ever applies to the C types in combination with a Bluetooth
sensor-switched product.
Twilight setting (response threshold)
The chosen response threshold can be infinitely varied from approx. 2 to
2000 lux.
– Control dial turned fully clockwise = daylight mode (depending on ambient
brightness)
– Control dial turned fully anti-clockwise = twilight operation (approx. 2 lux)
This function only ever applies to the C types in combination with a Bluetooth
sensor-switched product.
The control dial must be turned fully clockwise when adjusting the detection
zone and performing the walk test in daylight.
Night-light function
The night light provides illumination at approx. 10% of full light output. The light
only switches to maximum output (100%) in response to movement in the
detection zone (see Time setting). The light
then switches to the activated night light level.
Night light is ON when the level of light falls below the brightness threshold.
Night light is always ON when daylight mode is activated.
0 min
= soft light start / no night ON from twilight setting selected
10 min = soft light start + night light for 10 minutes
30 min = soft light start + night light for 30 minutes
= soft light start + night light all night long
This function only ever applies to the C types in combination with a Bluetooth
sensor-switched product.
What is soft light start?
The sensor-switched light features a soft light start function. This means that
when turned ON, the light is not switched directly to maximum output but con-
stantly builds up brightness to 100% within a short period of time. Brightness is
also gradually reduced when the light is switched OFF.
This function only ever applies to the C types in combination with a
Bluetooth sensor-switched product.
Manual override function (Fig� 6�1)
If an optional mains switch is installed in the mains supply lead, the following
functions are available in addition to simply switching light ON and OFF:
- 38 -