Technical Specifications - Solidyne HL 202 Manual De Usuario

Ocultar thumbs Ver también para HL 202:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TELEPHONE HYBRIDS
HL202 & 203VQ

4 TECHNICAL SPECIFICATIONS

TECHNOLOGY
AGC OUTPUT LEVEL
TELEPHONIC INPUTS
AUDIO SEND FILTERS
INPUT LEVEL
OUTPUT TO CONSOLE
SEND TO PHONE LINE
FEQUENCY RESPONCE
HARMONIC DISTORTION
NIVEL DE RUIDO
HYBRID REJECTION
BALANCE
OVERLOAD SAFETY
LINES ISOLATION
ALIMENTACION
DIMENSIONS
Active Hybrid with send and return gain, auto-adjusted by audio limiter and AGC. Balanced telephone
lines floating with ground isolation by Nickel-Ferrite transformers.
VQR System to improve the audio quality of telephone lines (HL203-VQ).
Constant level to console, independent from line level due to the action of the internal AGC. A 15 dB
phone level change causes less than 3 dB change at the Output
Output level control on the front panel. Nominal level +4 dBu, variable between -60/+8 dBu
Priority: The speaker at the Studios have priority over the caller, causing an attenuation fo 12 dB on
the incoming call.
HL202: 2 lines in conference with croosed gain. The 2 inputs for land lines or wired cell phone, are
isolated and floating with transformer.
HL203-VQ: Adds a third line through a cell linked by Bluetooth to avoid physical connections and
allow up to 10 meters away. The cell phone can be operated from HL203, receiving calls.
Band-Pass filters in send channel, limits response to 400 – 2.200 Hz to eliminate on-air sound
coloration.
Audio limiter to operate with signals from -5 to + 8 dBu.
Nominal + 4 dBm balanced 600 ohms or hi Z
Adjustable level with needle Vumeter.
Symetric output with XLR-3 connector.
0 dBm +/- 1 dB, measured over 2 KM artificial phone line
250 - 3.400 Hz +/- 1 dB (VQR off)
VQR on (HL203): improve the spectrum between 50 – 12.000 Hz
GAIN
Adjustable until 30 dB
Lower than 0,2 % at the console output at 1 kHz
S/R better than 75 dBA, measured over 2 KM artificial phone line, with
without VQR
Better than 40 dB @ send of +4dBu at 1 Khz. Measured over 2 KM artificial phone line.
15 wheels preset for each line.
Protection against overshoots with varistors SIOV (Siemens). Resist discharge capacitor charged to
2,000 V in laboratory tests
Independents inputs, balanced and floating with transformer Isolation 250 V/CA
220/115 V, 50/60 Hz with manual switch. 10 VA
19" Rack mounting 1 U height
Page 36
ENGLISH
VQR. Better than 60 dBA
Tabla de contenido
loading

Este manual también es adecuado para:

Hl 203 vq

Tabla de contenido