If you want to set parameters then need Combine with "M".
Reset operation:
In the shutdown, press and hold the "
parameter.
5.4 Parameter setting table and Fault code:
Short press "M" to query the status parameters of the unit
Parameter
Meaning
A
Inlet/Return Water Temp.
b
Coil Temp.
c
Ambient Temp.
d
Exhaust gas Temp.
E
Return Water Temp. Setting value in
Heating mode
F
Defrosting period
G
Exits defrost time
H
Return Water Temp. Setting value in
cooling mode
J
Temp. Difference to Restart heat
pump
L
With/Without Brown-out Protection
O
Anti-freeze
Ambient Temp.
P
Coil Temp. to entering defrosting
t
Coil Temp. To Quit Defrosting
U
Exhaust Temp. protection value
5.5 Fault code
Protection / Error
Inlet water temperature sensor failure
Coil Pipe sensor failure
Ambient temperature sensor failure
Ambient temperature too low
Exhaust gas temperature sensor failure
2021-2022
" button + "M" button for 10 seconds to restore the default value of the
protection
value
of
Page 11 / 61
Range
Default value
-19~99℃
-19~99℃
-19~99℃
0~120℃
15℃~40℃
27℃
10~80Min
40 Min
5~30Min
8 Min
8℃~28℃
27℃
1℃~10℃
2℃
0~1
-10℃~15℃
-5℃
-19℃~0℃
-1℃
1℃~30℃
20℃
80~120℃
110℃
Remarks
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
1
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Code
P1
P2
P3
E4
P4