Aqua Medic platinum line plus Manual De Instrucciones página 8

Ocultar thumbs Ver también para platinum line plus:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
The connections of the unit are (please refer to Fig. 4):
1. Tap water inlet – into the prefilter (6)
2. Waste water outlet (14) at the flush valve (3)
3. Pure water (permeate) (2)
4. Tap connection (no pict.)
Attach the tap connection to a 3/4" tap (cold water). If necessary, use a reduction piece (not included in
shipment).
3. Safety instructions
-
Do not operate the unit in rooms with high humidity.
-
Protect the unit from moisture, splash and condensate.
-
Disconnect the power pack from the mains before working on electronic components.
-
Before taking the unit into operation, check all housing parts and tube connections for leaks.
-
Not suitable as a toy for children.
4. Start up
First of all, install the membrane without the transparent packaging. Remove the tube from the screw cap of
the membrane housing, open the membrane housing and insert the membrane. Then tighten the membrane
housing and all 10" housings using the supplied wrench.
Fig. 2: Mounting the O-ring of the membrane's housing
Don't insert the O-ring of the membrane's housing into the screw cap but push it onto the housing.
Tighten the membrane's housing's lid with the wrench.
When the membrane is fitted and all tubes are mounted, you can open the water tap and insert the power plug.
Check all connections for leaks. The fittings are sealed with Teflon tape. If they are leaking, they can be sealed
using some Teflon tape. The system flushes automatically both at the start and during operation. The "Flush"
indicator lights up.
Fig. 3: Control unit platinum line plus
8
loading