Remote Control Setting; Error Codes - PNI BPL505S Manual De Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55

Remote control setting

Learn a remote control
Press the LEARN button, the LED lights up. Then press the button you want
to program on the remote control until the LED flashes and then goes out.
Now the remote control has been learned.
Remove a remote control
Press and hold the LEARN button until the LED lights up and then goes out.

Error codes

Code
Meaning
Err1
Limit optical meter
Exceeding the engine operating
Err2
limit
Err3
The motor rotor is blocked
Err7
The photocell is triggered
Airflow sensor. It is mounted on
the barrier to prevent collision
Err8
with the oncoming vehicle as
the barrier closes.
Solution
Check the optical meter wires
1. Check the optical meter
connection
2. Check the mechanical
system
1. Check the mechanical system
2. Check the motor wires
Remove objects that intersect
the photocell beam
Remove objects that block the
pressure sensor
17