Flat Type Printhead - Load Transfer Ribbon

NOTICE!
For the thermal transfer printing method it is necessary to load a ribbon, otherwise when using the printing system
in direct thermal print it is not necessary to load a ribbon. The ribbons used in the printing system have to be at
least the same width as the print media. In case the ribbon is narrower than the print media, the printhead is partly
unprotected and this could lead to early wear and tear.
E
D
C
NOTICE!
Before a new transfer ribbon roll is loaded, the printhead must be cleaned using printhead and roller cleaner
(97.20.002). The handling instructions for the use of Isopropanol (IPA) must be observed. In the case of skin or
eye contact, immediately wash off the fluid thoroughly with running water. If the irritation persists, consult a doctor.
Ensure good ventilation.
Open the cover of printing system.
Open the printhead (C) by turning the pressure lever (D) anticlockwise.
CAUTION!
Risk of scraping when inserting the transfer ribbon res. when removing the used transfer ribbon!
Be careful with the spring steel plate edges!
Load the transfer ribbon roll (A) with outer winding onto the unwinding roll (B).
Place an empty ribbon roll on the rewinding roll (E).
Lead the transfer ribbon below the printhead (C).
Fix the ribbon with an adhesive tape in rotating direction at the empty roll of the rewinding roll (E).
Pay attention to the rotation direction of transfer ribbon rewinder anticlockwise.
In order to move the printhead (C) down, turn the pressure lever (D) in clockwise direction until it locks.
Close the cover of printing system.
NOTICE!
As for the electrostatic unloading the thin coating of the thermal printhead or other electronic parts can be
damaged, the transfer ribbon should be antistatic.
The use of wrong materials can lead to printing system malfunctions and the guarantee can expire.
CAUTION!
Impact of static material on people!
Use antistatic transfer ribbon, because static discharge can occur when removing.