11. Possible causes of failure
Problem
The compressor
does not start.
The compressor
starts but there is no
pressure.
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
For EU countries only
Never place any electric power tools in your household refuse.
To comply with European Directive 2012/19/EC concerning old electric and electronic equipment and
its implementation in national laws, old electric power tools have to be separated from other waste and
disposed of in an environment-friendly fashion, e.g. by taking to a recycling depot.
Recycling alternative to the return request:
As an alternative to returning the equipment to the manufacturer, the owner of the electrical equipment
must make sure that the equipment is properly disposed of if he no longer wants to keep the equipment.
The old equipment can be returned to a suitable collection point that will dispose of the equipment in
accordance with the national recycling and waste disposal regulations. This does not apply to any ac-
cessories or aids without electrical components supplied with the old equipment.
Please note that batteries and lamps (e.g. light bulbs) must be removed from the tool before it is dispo-
sed of.
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers ac-
companying products is permitted only with the express consent of the Einhell Germany AG.
Subject to technical changes
Anl_TE_AC_36_6_8_Li_OF_SPK13.indb 22
Anl_TE_AC_36_6_8_Li_OF_SPK13.indb 22
GB
Cause
1. No power supply
2. Outside temperature is too low.
3. Motor is overheated.
1. The non-return valve leaks.
2. The seals are damaged.
3. The drainage cock for condensati-
on water has a leak.
1. The hose connections have a leak.
2. A quick-lock coupling has a leak.
3. Insuffi cient pressure set on the
pressure regulator.
- 22 -
Solution
1. Check the rechargeable batteries
2. Never operate with an outside tem-
perature of below +5° C.
3. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
1. Have a service center replace the
non-return valve.
2. Check the seals and have any da-
maged seals replaced by a service
center.
3. Check the drainage cock and repla-
ce if necessary.
1. Check the compressed air hose
and tools and replace if necessary.
2. Check the quick-lock coupling and
replace if necessary.
3. Increase the set pressure with the
pressure regulator.
19.04.2022 08:43:56
19.04.2022 08:43:56