Adjusting the minimum pressure
The gas pressure at the burner must be checked through the
pressure outlet positioned on the gas valve outlet pipe using a
water pressure gauge or a micro pressure gauge
- Remove the protection cover (G).
- Disconnect the power cable (12V) from the modulating coil.
- Adjust the minimum pressure to the value indicated in the table
below, screwing down (to increase) or unscrewing (to decrease)
the adjusting screw (I).
- Reconnect the power cable (12V) of the modulating coil.
- Seal the regulator with a cover (G).
As  proof  of  conversion  apply  the  adhesive  label  provided  in  the  conversion  kit  above  the  technical  data  plate 
bearing the information on the gas for which the boiler was set up at the factory.