Installing the product onto the furniture
After making the connections, surround the edges of the hob (as a strip) with the epdm foam
provided together with the installation parts and lean it. Slightly tighten the fixing hook and
use a curved knife to eliminate excess epdm foam.
Gloves must be worn to avoid accidents during installation.
Installation information of the appliance
Warning:
This appliance must be installed in well-ventilated areas in accordance with the
applicable legislation. Please read the instructions before installing or using the
product.
Warning:
This product is not connected to a system for discharging combustion products.
This product must be connected and installed in accordance with the applicable
installation norms. Special attention must be paid for requirements regarding
ventilation.
The person installing the appliance must observe rules and norms regarding ventilation and
discharge of exhaust gases.
Your hob has been designed to be installed on commercially-available standard
countertops.
Thickness of the working top must be 30 mm minimum.
Materials used on the counter surface and in partitions under the counter must be
resistant to 100 °C minimum.
A safety distance must be left between the hob and the kitchen walls.
The recess for the hob on the countertop must be like the one in the figure. (Figure 2 /
Figure 3)
The distance between the hob base and the partition must be 25 mm minimum. (Figure
2)
The distance between the top of the hob and the other appliance (e.g. ventilation hood)
must be 700 mm minimum. (Figure 2)
If 60 cm hobs will be placed on top of a built-in oven that does not have a cooling
system, it is recommended to drill a ventilation hole of at least 300 cm
proper air circulation. If you will place a 75 cm or 90 cm hob, the oven must have a
cooling fan.
10
2
to provide