Message displayed
This symbol may appear
on the scanner during
en
data transfer between the
scanner and monitor.
This symbol may appear
on the scanner during
data transfer between the
scanner and monitor.
This symbol may appear
during the transfer of data
between the PS 200 S
scanner and the PSA 55
adapter.
A stop symbol generally
indicates a fatal error in
the scanner.
A stop symbol generally
indicates a fatal error in
the scanner.
30
Fault
Data is not being trans-
ferred.
Data is not being trans-
ferred.
Data is not being trans-
ferred.
One of these symbols
may be displayed imme-
diately after the scanner is
switched on.
Possible cause
Data transfer was inter-
rupted or a connection
could not be established.
Indicates that the scanner
or monitor may be defec-
tive.
Indicates that the scanner
or adapter may be defec-
tive.
They indicate a possible
electronic fault.
Remedy
Check that the scanner
and monitor are posi-
tioned within the maxi-
mum range of 30 cm (12")
and that they are correctly
aligned with each other.
Make sure that the at-
mosphere is as dust-
free as possible and that
the infrared windows on
both scanner and mon-
itor are clean and not
badly scratched. Badly
scratched windows must
be replaced by Hilti Ser-
vice.
Try to hold the moni-
tor and scanner steady
and in correct alignment
with each other until data
transfer is completed.
Remedy the problem by
switching the units off and
on or adjusting their align-
ment with each other.
NOTE
Data is not lost in the
event of an interruption
in data transfer. Data is
deleted from the scanner
only once all scan data
has been correctly trans-
ferred and the Confirm
button on the scanner is
pressed.
If the error message is still
displayed the tool must
be returned to a Hilt Ser-
vice Center.
Remedy the problem by
switching the unit off and
on or adjusting its align-
ment.
Switch the scanner off
and then on again.
If the error message re-
appears the tool must be
returned to Hilti for repair.