Eu Conformity - Denios SPILLGUARD CONNECT Manual De Instrucciones

Ocultar thumbs Ver también para SPILLGUARD CONNECT:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4.3 Alarm procedure
After detecting a leak the following alarms
are given:
5 beeps, 15 s pause
Fast flashing during the pause
LED
SpillGuard® connect transmits the
specified text message to the
recipient address saved
the status (alarm) on the web interface
W
is updated
the alarm text saved is sent by text
W
message/e-mail to the recipient
addresses saved (see chapter 3.4).
Press the Push button (>1s and <10s)
1.
1 beep
The alarm is turned off.
24/48
i
When handling hazardous substances,
observe the safety instructions in
the safety data sheet for the leaked
hazardous substance.
Carry out measures to clean up the leak.
1.
WARNING
• Hazard from direct contact with the
hazardous substance
• Injury possible to hands, eyes etc.
• Wear personal protective equipment (PPE)
Press the Push button (>1s and <10s) to
1.
turn off the alarm.
Clean the sensor surface with a soft,
2.
lint-free cloth. In this case, SpillGuard®
connect can be used again.
Switch on and calibrate SpillGuard®
3.
connect (see chapter 4.1 and 4.2).
4.4 False alarm
Under certain climatic conditions
condensation can form on the sensor surface.
This can trigger a false alarm.
Press the Push button (>1s and <10s)
1.
to turn off the alarm.
2.
Clean the sensor surface with a soft,
lint-free cloth. In this case, SpillGuard®
connect can be used again.
3.
Switch on and calibrate SpillGuard®
connect (see chapter 4.1 and 4.2).
More information
Further information on alarms,
decommissioning and disposal for example
can be found in the operating instructions.
The operating instructions can be found here:
www.denios.com/spillguard

5. EU conformity

SpillGuard® connect is certified in accordance
with directive 2014/34/EU (ATEX directive).
Production is monitored by regular and
independent inspections for continuous
compliance with legal and normative
requirements.
This declaration of conformity as well as
confirmation of conformity with directives:
2014/34/EU (ATEX)
W
2014/53/EU (RED)
W
2014/30/EU (EMV)
W
2011/65/EU (RoHS 2)
W
can be found at the following address:
www.denios.com/spillguard
SpillGuard® connect Quick Guide | 276016 | Rev. 1
25/48
Tabla de contenido
loading

Tabla de contenido