A
TTENTION
held in place by the rack.
4. After the maintenance and/or cleaning procedure, repeat points 1 and 2 in reverse
order.
If the power cable is damaged, it must be replaced by the manufacturer or its service agent,
or in any case by a competent person, in order to prevent any risk.
15. TROUBLESHOOTING
If you experience problems during installation or normal use of the unit, these are some
possible causes. Also refer to the indications of the R
Problem
The actuator
does not
operate
The actuator
turns on but
does not work
16. Environmental protection
All materials used in the manufacture of this appliance are recyclable.
We recommend that the device itself, and any accessories, packaging, etc. be sent to a
centre for ecological recycling as established from laws in force on recycling.
The device is mainly made from the following materials: aluminium, zinc, iron, plastic of
various type, cuprum. Dispose materials in conformity with local regulations about
removal.
17. Certificate of guarantee
The manufacturer will guarantee good function of the appliance. The manufacturer shall
undertake to replace defective parts due to poor quality materials or manufacturing
defects in accordance with article 1490 of the Civil Code.
The guarantee covers products and individual parts for 2 years from the date of
purchase. The latter is valid as long as the purchaser possesses proof of purchase and
completion of all agreed conditions of payment.
Guarantee of good function of appliances agreed by the manufacturer implies that the
latter undertakes to repair or replace free of charge and in the shortest period possible
any parts that break while under warranty.
: there is a
DANGER
Possible Cause
Power failure at source
Connection cable not connected
or with a loose wire
The power supply is different
Electrical wiring error
Connection with other
incompatible machines
that the window may fall since it is no longer
LED:
ED
Check the status of the circuit
breaker fuse
Check all electrical connections to
the gearmotor
Check that the actuator is powered
with the same type of voltage as
indicated on the technical data label
Check electrical connections of
individual wires and their function
Check that the machines connected
to the battery are compatible by
consulting the relative instruction
manuals.
52