Mitsubishi Electric PUZ-HA Serie Manual De Instalación página 10

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6. Electrical work
6.2. Field electrical wiring
Outdoor unit model
Outdoor unit power supply
Breaker size
Minimum circuit ampacity
Maximum rating of overcurrent protective device
Outdoor unit power supply
Outdoor unit power supply earth
Indoor unit-Outdoor unit
Indoor unit earth
Remote controller-Indoor unit
Outdoor unit L1-L2
Indoor unit-Outdoor unit S1-S2
Indoor unit-Outdoor unit S2-S3
Remote controller-Indoor unit
*1. Max. 45 m, 147 ft
If 2.5 mm
2
used, Max. 50 m, 164 ft
If 2.5 mm
2
used and S3 separated, Max. 80 m, 262ft
*2. The 10 m, 30 ft wire is attached in the remote controller accessory. Max 1500 ft
*3. The figures are NOT always against the ground.
S3 terminal has 24 VDC against S2 terminal. However between S3 and S1, these terminals are NOT electrically insulataed by the transformer or other device.
*4. Please follow applicable federal, state, or local codes to prevent potential leakage/electric shock. Or install a ground fault interrupt for the prevention of leakage and electric shock.
Notes: 1. Wiring size must comply with the applicable local and national code.
2. Use copper supply wires.
3. Use wires rated 600V or more for the power supply cables and the indoor/outdoor unit connecting cables.
4. Install an earth longer than other cables.
Warning:
In case of A-control wiring, there is high voltage potential on the S3 terminal caused by electrical circuit design that has no electrical insulation between power
line and communication signal line. Therefore, please turn off the main power supply when servicing. And do not touch the S1, S2, S3 terminals when the power
is energized. If isolator should be used between indoor unit and outdoor unit, please use 3-pole type.
Warning:
• Turn on the main power when the ambient temperature is -20°C, -4°F or higher.
• In below -20°C, -4°F condition, it needs at least 4hr standby to operate in order to warm the electrical parts.
Never splice the power cable or the indoor-outdoor connection cable, otherwise it may result in a smoke, a fire or communication failure.
en
9
HA24
Single, 208/230 V, 60 Hz
*4
25 A
17 A
27 A
2 × Min. AWG 12
1 × Min. AWG 12
*1
*1
*2
*3
*3
*3
*3
208/230V
Single phase
Isolator
S1
A-Control
S2
Outdoor Unit
S3
HA30
Single, 208/230 V, 60 Hz
Single, 208/230 V, 60 Hz
35 A
24 A
40 A
2 × Min. AWG 10
1 × Min. AWG 10
3 × AWG 14 (polar)
1 × Min. AWG 14
2 × AWG 22 (Non-polar)
208/230 VAC
208/230 VAC
24 VDC
12 VDC
3 poles isolator
HA36
HA42
Single, 208/230 V, 60 Hz
35 A
40 A
26 A
36 A
42 A
60 A
2 × Min. AWG 8
1 × Min. AWG 8
S1
A-Control
S2
Indoor Unit
S3
Tabla de contenido
loading

Tabla de contenido