5.3.2

Replacing the welding torch body/cable (only for CP70C DAR)

• Unscrew the cable gland F Fig.7;
• Unscrew the retention dowel G, then handle M, pull it back until all cables are shown (see Fig. 8).
• Disconnect connector A and connector B (pilot arc) shown in fi g.8.
• Remove heat shrinking hose C and unscrew nut D (wrench #13) by keeping fi tting E (wrench #11) fastened.
• Replace the welding torch body.
• Screw the fi tting D according to the arrow direction - Fig .8
• Tighten fi ttings, introduce the heat-shrinking hose C and use a small heat source to warm it up. Make sure that
fi ttings are completely covered.
• Reconnect connectors A and B, screw in the handle M and then, the retention dowel G.
• Screw again cable gland F.
5.4

Replacing the grip with push-button CP-70C mar

• Unscrew the 6 screws V Fig.3 and remove the LH grip.
• With reference to Fig.4, lift the welding torch body with cable and disconnect connector A (push-button) .
• Replace the grip with push-button, connect connector A and introduce it inside the grip, as shown in fi gure 4, and
then position the welding torch body with cable inside the RH grip seat.
• Fasten the LH side of the grip making sure not to fl atten any wire between the grip rims and then screw the 6 screws
V again.
16
G
C
M
A
D
B
F
Fig. 7
Fig.8