Installing The Outlet Pipes - Cinderella COMFORT Manual Del Producto

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 159

2.5.1 INSTALLING THE OUTLET PIPES

DIAMETER VENT PIPE
110mm
110mm
110mm
35 mm
40 mm
!
415 mm
OUTLET DIRECTION
Horizontal flue pipe
Vertical flue pipe
Vertical flue pipe
C
280
Ø 111mm
155mm
REFERENCE
BENDS
C
(Not allowed)
A
None
B
2 x 45° bends
C
NOTE!
When adjusting the pipe length, please notice
that the pipe will enter 35 mm into the appliance
flue terminal, and will have to be calculated into
the planning of your installation.
NOTE!
When installing the pipe vertically, straight up
from the appliance, please notice that the
minimum distance from the wall must be
280mm.
NOTE!
The Original Cinderella Installation Kit includes
5 x 1066 mm pipes to be used on the outlet
installation, the pipes are delivered with socket
and gasket for simple installation. When
installing the pipe on the outer wall, you will have
to enter the pipe from the external to the inside.
MAXIMUM PIPE LENGTH
1.0m
6.0m
5.0m
NOTE!
The center of
the appliance
flue terminal is
415 mm from
the floor level.
9