TREND NETWORKS FIBERMASTER Guía De Referencia Rápida página 6

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

EN
For the purposes of this quick start guide please select Auto followed by the
check box at the bottom of the screen.
Setting Limits for Pass/Fail
Standard Limits are pre-set limits/thresholds against which the traces are
measured for pass/fail analysis to
6
www.trend-networks.com
Set the Refractive Index if known.
Select Load Default if the index
of refraction (IOR) and/or helix
factor are unknown.
Set the End Of Fiber (EOF)
Detection Threshold.
Enough information has now been
entered to conduct an Auto Test.
If Auto is selected, the averaging
time, range and pulse width will be
automatically set based on analysis
conducted by the OTDR. Select
Manual and those parameters
automatically set in Auto Mode will
be available for adjustment.
certify network links.
Standard limits will be highlighted,
There are 5 pages of pre-set limits/
thresholds to which the test will be
measured to determine Pass/Fail.
The first page lists cabling
standards and pages 2-5 lists
application standards.
Manual allows for setting user
defined Pass/Fail thresholds
If a standard set of limits is
selected, when the check box
at the bottom of the display is
touched, a page confirming those
standards will be shown, such as
this sample page.
240810 Rev 1.
Tabla de contenido
loading

Tabla de contenido