See separately operating instructions!
Check the following before operation:
̇
Establish the weight of the load and choose a trolley with sufficient capacity to lift the load safely.
̇
Locate the centre of gravity of the load or machine, to find the safest suitable lifting point.
Ensure, that:
̇
the trolley is standing on a firm and level surface.
̇
the base of the trolley body is in full contact with the floor surface
During lifting always ensure that the load is secure. If the load begins to tilt, lower onto chocks, move the trolley towards
the centre of gravity and recommence lifting.
On loads with high centres of gravity always use 4 trolleys together.
Attention: Danger of injury
̇
Never lower a load directly onto the trolleys wing a crane or similar overhead lifting device.
î Break of and / or destruction of the trolley will be the consequence!
̇
Never use the trolleys on a slope
̇
Never position the trolleys under sheet steel frame, a sheet steel panel or other points of lifting, with
are not rigid enough to support the weight of the load!
Always consult the manufacturer about suitable jacking points.
̇
î The deformation of the frame will be the consequence!
̇
Grease the cylinder slides regularly (hydraulic oil HLP46)
̇
Oil change of the pumps: See separately operating instructions!
APPROPRIATE HAND PUMPS
Appropriate hydr. hand pump
PV-K - (for 2 pc. RLZ2 )
PV-K - (for 2 pc. RLZ2K )
PV-K - (for 2 pc. RLZ4 )
PV-K - (for 2 pc. RLZ5 )
OPERATING OF THE HAND PUMP

WHAT TO DO BEFORE OPERATION

DURING LIFTING

HOW NEVER TO USE THE TROLLEY

STORAGE AND MAINTENANCE

INSTRUCTIONS FOR THE USE OF RLZ
Compression adjusted to
210 bar
210 bar
420 bar
520 bar