BMR Tummy Lift IM Rev 2_USA 21/03/2011 11:02 Page 17

technical specifications

Caring for your
ACTIVATOR
Your
should not be allowed to get wet or be left in excessive sunlight. It may
ACTIVATOR
be cleaned regularly using a soft cloth, lightly dampened in soapy water. Do not allow
the interior of the
to become wet. Do not use detergents, alcohol, spray
ACTIVATOR
aerosols or strong solvents on your
Access to the interior of the
ACTIVATOR
If your
is damaged, you should not use it but should return it to
ACTIVATOR
local distributor for replacement or repair. Repairs, service and modifications may not
be carried out by anyone other than qualified service personnel authorized by
: Under no circumstance should anything other than the correct type of
IMPORTANT
batteries (rechargeable batteries 3.6V NiMH) be used with your
be purchased from the Careline.
Disposing of the GelPads and batteries
Used GelPads and batteries must never be disposed of in a fire but in accordance with
national or state laws governing the disposal of such items.
: The signal gradually increases to a peak intensity level at the start of the contraction
NOTES
phase (i.e. ramp up) and gradually decreases to nothing at the start of the relaxation phase
(i.e. ramp down). When the
symbol is flashing, the stimulus is significantly reduced.
Beauty Series Accessories:
You can purchase all accessories at www.bmrbeautyseries.com. Under no circumstances
should anything other than
BMR LIFT
(Type 390) or charger. Any others may not be compatible with the product and could
degrade the minimum safety levels.
Garment (E:10)
BMR TUMMY LIFT
GelPads:
•1 large GelPad (Type 706 or 709)
BMR TUMMY LIFT
•2 small GelPads (Type 707 or 710)
Garment (E:30)
BMR BOTTOM LIFT
GelPads:
•4 large GelPads (Type 716)
BMR BOTTOM LIFT
Garments (E:60)
BMR ARM LIFT
GelPads:
•4 small GelPads (Type 715)
BMR ARM LIFT
Belt Extender
Battery pack (3.6V, NiMH)
Battery Charger (EU - 2504-0303)
Battery Charger (US/Japan - 2504-0302)
Charger complies to IEC 60950 and UL 1950, Input: nominal voltage 100-240V, frequency
50-60Hz, current 90mA. Output: 6V / 550mA. Do not use any other chargers or any other
power supplies.
Product Type: 391
Intended use: Muscle stimulator
Classification: Internally powered equipment, Class II charger, Type BF applied parts.
Waveform: Symmetrical bi-phasic square waveform when measured into a resistive load.
Environmental Specifications:
Operating:
Temperature Range: 0 - 35°C (32 - 95°F)
Humidity:
Storage:
Temperature Range: 0 - 35°C (32 - 95°F)
Humidity:
16
All manuals and user guides at all-guides.com
.
ACTIVATOR
is not required for maintenance purposes.
ACTIVATOR
accessories be used with your
ACTIVATOR FOR LIFT
20 - 65 % RH
20 - 85 % RH
Description of your
There are a number of technical markings on your
follows:
The
ACTIVATOR
Park West, Galway, Ireland.
The
requires 1 x 3.6 volt (NiMH) DC battery pack DC is indicated by the symbol:
ACTIVATOR
The Output Frequency indicates the number of pulses per second transmitted by the
. This is measured in hertz, which is indicated by "Hz".
ACTIVATOR
or your
BMR
Output (RMSA) means the maximum output root mean square current for each channel.
Output (RMSV) means the maximum output root mean square voltage for each channel.
.
BMR
!
This symbol means "Attention, consult the accompanying documents".
. These can
This symbol means type BF applied parts.
This symbol on your
Medical Device Directive (93/ 42/EEC). 0366 is the number of the notified body
0366
(VDE).
SN stands for 'serial number'. Inside the box, on the back of the
number specific to this
manufacture, where "P" denotes 2010, "Q" denotes 2011 etc.
The belt's batch number is represented on the belt packaging by the number corresponding
with the LOT symbol.
Rated Outputs – Voltage/Currents: E:10
Parameter
Output RMSV
Output RMSA
Output Frequency
DC Component: Approx.
Positive Pulse Width:
Negative Pulse Width:
Interphase Interval:
Attention:
The
ACTIVATOR
At the end of the product lifecycle, do not throw this product into the normal household
garbage, but bring it to a collection point for the recycling of electronic equipment.
Some product materials can be re-used if you bring them to a recycling point. By
re-using some parts or raw materials from used products you make an important
contribution to the protection of the environment. Please contact your local authorities
if you need more information about collection points in your area.
Waste Electrical and Electronic Equipment can have potentially harmful effects on
the environment. Incorrect disposal can cause harmful toxins to build up in the air,
water and soil and can be harmful to human health.
Belt Materials:
Outer material: 100% Nylon, Binding: 82% Nylon, 18% Elastane, Hook & Loop: 100%
Nylon, Foam: 100% Polyurethane
's symbols:
ACTIVATOR
ACTIVATOR
and belt are manufactured for Bio-Medical Research Ltd, Parkmore Business
is to indicate conformity to the requirements of the
ACTIVATOR
Conforms to UL STD 60601-1.
Certified to CAN/CSA.
STD C22.2 NO 601.1
. The letter preceding the number indicates the year of
ACTIVATOR
500
7.35V
14.7mA
50-70Hz
0 C
200-315µs
200-315µs
100 µs
can deliver currents in excess of 2mA/cm 2 if used with incorrect GelPads.
. These can be explained as
is the serial
ACTIVATOR
1K
1K5
13.1V
15.5V
13.1mA
10.3mA
50-70Hz
50-70Hz
0 C
0 C
200-315µs
200-315µs
200-315µs
200-315µs
100 µs
100 µs
17