Modifying The Operating Parameters Of The Recharging Station - Gewiss JOINON EASY GW68122 Manual De Uso E Instalación

Unidad de carga para vehículos eléctricos
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

JOINON EASY electric vehicle recharging unit
13.
40
To update the firmware, proceed as follows:
#
Action to be carried out
1
Disconnect the power supply to the product by turning off the main switch
2
Open the charging station to access the electronic board
3
Remove the microSD card from its slot on the electronic board
4
Insert the microSD card in the specific slot on your PC, to open the folder
Paste the update file in the main folder of the microSD card
5
NOTE: contact GEWISS SAT customer service for the most recent file (which will also be available on the
GEWISS website)
6
Insert the microSD card in the slot on the electronic board
7
Close the charging station and reconnect the power supply to launch the updating procedure
8
Once the command has been executed, the station will return to standby

MODIFYING THE OPERATING PARAMETERS OF THE RECHARGING STATION

Once the product has been installed, certain station operating parameters can be modified via a text file to be saved
on the microSD card inserted in the charging station itself.
Use a computer to create a text file renamed "config.ini", where you can insert the parameters you want to modify. The
parameters must be added as indicated below.
The parameters that can be modified are:
Function description
Name of the parame-
ter to be used
Maximum input current MAXAMPERAVAILABLE
Date and time
DATETIME
Identification of the
SOCKETMODEL
recharging connector
LOG level
LOGLEVEL
Available options, and examples
The input current set in the factory can be altered to suit
the real availability and avoid problems during recharging.
To do this, use the MAXAMPERAVAILABLE parameter
Example
MAXAMPERAVAILABLE=64
If the station date is wrong, it can be updated using the
DATETIME value. The format is YYYY/MM/DD-hh:mm
Example
DATETIME=2019/08/15-14:30
If necessary, the recharging connector on the product can
be reconfigured (flush-mounting socket-outlet or mobile
connector).
The options are:
Flush-mounting socket-outlet, Type 2= G
Mobile connector = M
Example
SOCKETMODEL=G
The LOG level saved by the recharging station on the
microSD card can be modified using the LOGLEVEL
parameter. You can choose from 5 levels ranging from 0
(limited wordiness) to 4 (high degree of wordiness)
Example
LOGLEVEL=1
Tabla de contenido
loading