Rfid - Gewiss JOINON EASY GW68122 Manual De Uso E Instalación

Unidad de carga para vehículos eléctricos
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TYPE
VERSION
POWER SUPPLY
CABLE OR
FREE
SOCK-
ET-OUTLET

10.2. RFID

The charging station activates the recharging session once an RFID card (enabled for charging - i.e. added to the
local list of authorised cards) has been swiped across the screen.
There are two ways of adding an RFID card to the local list:
METHOD 1
#
Action to be carried out
Swipe the MASTER key across the RFID scanner to enable
1
the storage phase
Take each card that you want to add to the list and swipe
them across the RFID scanner.
2
The colour of the RGB LED indicates correct acquisition
To quit the RFID card storage menu, swipe the MASTER key
3
twice across the RFID scanner.
METHOD 2
#
Action to be carried out
1
Disconnect the power supply to the product by turning off the main switch
2
Open the charging station to access the electronic board
3
Remove the microSD card from its slot on the electronic board
4
Insert the microSD card in the specific slot on your PC, to open the folder
Create a .csv file called "RFID.csv".
The file structure must be:
UID1;
UID2;
5
Example
A14HNL5T;
DZ47TBD5;
....
6
Save the file in the main directory of the microSD card
7
Insert the microSD card in the slot on the electronic board
8
Close the charging station and reconnect the power supply to launch the updating procedure
9
Once the command has been executed, the station will return to standby
Contact GEWISS SAT customer service for the UID codes of your RFID cards; you will be asked to give the number
on the cards.
FACTORY
VALUE
20
SINGLE-PHASE
32
Selector
NOMINAL
position 1
settable
value
VALUE 60%
20
12
16
9.6
14
8.4
12
7.2
32
19.2
25
15
20
12
16
9.6
14
8.4
12
7.2
RGB LED status
From fixed green to flashing white
Fixed green for 2 seconds
From flashing white
to flashing red
to fixed green
Selector
position 2
VALUE 30%
6
6
6
6
9.6
7.5
6
6
6
6
37
Tabla de contenido
loading