Spare Parts - MIL'S ARICA 11 Manual De Utilización

Bombas de vacío secas y compresores
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

 
The instructions for replacing intake filter or vanes are available upon request. 
 
N.B.: The times indicated above are given purely for guidance. 
They will depend on how the machine is used and may thus vary. Consult us for further information. 
 
4.3.
Spare parts 
Use Original Spare Parts to replace pump parts. 
When purchasing spare parts, always quote the serial number and model of the pump (these can be found on 
the identification plate) as well as the spare part purchase number. 
 
 5.
DISMANTLING 
 
Disposal operations involve risks of cutting, shavings protection, entanglement, contact with 
moving parts and contact with chemicals. Operators should use the appropriate personal 
protective equipment. 
 
Before any dismantling operation, make sure that the pump does not present any risk generated by substances 
drawn. See safety sheet on SECTION 6 
 
The  pump  must  be  dismantled.  The  materials  must  be  sorted,  collected,  recovered  according  to  current 
regulations. 
The main wastes to be recovered are: 
‐ 
Metallic materials 
‐ 
DEEE 
 
The  collection  and  recovery  must  be  done  by  service  providers  authorised  in  accordance  with  the  current 
regulations. 
519924.03 
 
ARICA 11‐16‐26‐40‐61‐80‐100 
 
 6.
 
Problems 
The pump does not run
The pump cannot reach 
stated vacuum 
 
Pump is noisy
 
Pump runs hot
 
 7.
 
See annex 
 
 8.
 
See annex 
 
 
 
TROUBLESHOOTING 
Possible cause
‐No voltage.
‐Thermal switch has tripped. 
‐Room temperature is too low. 
‐Motor wiring damaged. 
‐Suction of unpermitted substances.
‐Intake filter obstructed (if 
present). 
‐Wrong power supply to motor. 
‐Discharge clogged. 
‐Vanes worn out. 
‐Motor coupling damaged (if 
present). 
‐Bearings damaged. 
‐Vanes worn out. 
‐Discharge clogged. 
‐Motor fan guard damaged. 
‐Motor coupling damaged (if 
present). 
‐Bearings damaged. 
‐Vanes worn out. 
‐Discharge clogged. 
‐Motor fan guard damaged. 
SAFETY SHEET 
SPARE PARE LIST 
Solution
‐Provide power supply. 
‐Identify reason and activate switch. 
‐Restore room temperature to allowed 
range. 
‐Contact Service Department. 
‐Contact Service Department. 
‐Replace the filter cartridge. 
‐Check power supply. 
‐Check couplings at outlet. 
‐Contact Service Department. 
‐Contact Service Department. 
‐Contact Service Department. 
‐Contact Service Department. 
‐Check couplings at outlet. 
‐Contact Service Department. 
‐See point 6.2.1.
‐Install an auxiliary ventilator. 
‐Contact Service Department. 
‐Check power supply. 
‐Check couplings at outlet. 
10 

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Arica 16Arica 26Arica 40Arica 61Arica 80Arica 100