Porsche 9Y0.915.686 Manual página 23

Ocultar thumbs Ver también para 9Y0.915.686:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
Troubleshooting: Problems and solutions
Problem
Possible cause
In the Web Application overview,
On the EEBus device (e.g. Porsche charger),
no output is displayed on the EE-
the EEBus pairing was not successful
Bus device
No phase assignment in Web Application
Power sources or configured
No cables connected to the voltage measure-
power consumers show no or an
ment
incorrect output
Current sensors are connected the wrong way
round
Current sensors are not or are incorrectly con-
figured
No or incorrect current sensors configured for
power consumers
The fuse trips despite active
Current sensors are connected the wrong way
overload protection
round
Remedy
e
Perform EEBus pairing on the EEBus device again and boost the communi-
cation signal, if required (WiFi or PLC).
g Note the EEBus device
instructions.
e
In the HOME SETUP of the Web Application, assign phases to the EEBus
device by specifying the current sensors.
e
For information on the Web Application, refer to the instruc-
tions at https://www.porsche.com/international/aboutporsche/e-per-
formance/help-and-contact/
e
Qualified electrician attaches the neutral wire and the external wire via the
plug connector J400 to the energy manager.
e
Qualified electrician checks whether the arrow of the current sensor is
pointing in the direction of consumption and whether the cable is correctly
connected to plug connectors J200, J300 and J301.
e
Check whether the connection positions of the current sensors on the
energy manager correspond to the configuration in the Web Application,
HOME SETUP (CT#). In addition, the configured phases of the current
sensors must correspond with the phases of the voltage measurement.
e
In the Web Application, HOME SETUP, check whether (the correct) current
sensors have been assigned to the electrical loads.
e
Qualified electrician checks whether the arrow of the current sensor is
pointing in the direction of consumption and whether the cable is correctly
connected to plug connectors J200, J300 and J301.
21
Tabla de contenido
loading

Tabla de contenido