ATH-Heinl ATH-W Manual De Instrucciones página 93

Ocultar thumbs Ver también para ATH-W:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 239
To finish the process, press the A↑ button 4 time
2.7.9.
1. Position the gauge to "0"
2. Press the key combination STOP + < 5 g
3. The display shown opposite will appear
4. Position the gauge to "100 mm"
5. Press the ALU button
6. The display shows [CAL] – [215] / [235]
7. Position the gauge to "215 mm / 235 mm". When doing so,
position the measuring tip to the outer edge of the entry
cover.
8. Press the ALU button
9. The display shows [CAL.] – [15.0]
10. This value can be changed using D+ / D-
11. Confirm with [ALU].
12. Then secure an appropriate wheel (e.g. 16") on the machine
13. Next, position the plunge on the edge of the wheel rim
14. Press the ALU button
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2021-10
Service calibration of the gauge
4x
- 32 -
+