Symptoms
Different balancing
results
1
Buttons do not respond
Product shows (heavy)
rust damage
Motor / electric
Engine does not or only
sporadically brakes
Motor makes noises
Building circuit breaker
blows
Other causes of
"erroneous" balancing
results
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2021-10
Cause
Balancing machine is not properly
anchored to the ground
Incorrect calibration
Balancing shaft not tight
Bent shaft
Piezo sensors not fixed or
defective
Rim is not clean or is warped
Button board is not connected to
the control board or cable
connection is defective
Damage or lack of corrosion
protection, possibly maintenance
Brake resistor defective or not
connected.
Brake resistor defective or not
connected.
Damaged motherboard
The condenser is defective or not
connected.
Main machine switch is not
connected correctly or there is a
contact error.
Defective motherboard.
Use of different adapters and
resulting tension errors.
Tensioning with cones over a
worn middle hole in the rim can
cause differences of up to 10g.
Imbalanced tyres on the vehicle
may be the result of an
imbalanced brake drum or disc or
worn fastening bores in the rim
or brake.
ALWAYS USE ORIGINAL PARTS AND ACCESSORIES.
Solution
Check the floor anchor
Re-calibrate
Check the balancing shaft
attachment
Check the balancing shaft
Check the strength of the piezo
sensors mounting screws or replace
them
Check the rim
Check the connection as well as the
line.
Remove rust, clean and restore
surface.
Check brake resistor or connection
Check brake resistor or connection
Contact ATH service
Check condenser or connection
Check the electrical connection
Contact ATH service
When using adapters, please
observe the installation instructions.
Repair or use special adaptations of
rims or materials
In such cases, readjustment without
first removing the wheel is advised.