Cebora SOUND MIG 3540/TS SPEED STAR Manual De Instrucciones página 21

Ocultar thumbs Ver también para SOUND MIG 3540/TS SPEED STAR:
Idiomas disponibles

Idiomas disponibles

CEBORA S.p.A.
"Mot"
Excessive error Wire Feeder Motor
(57)
current.
58
Firmware versions misalignment error.
L1 Mains Phase voltage lower than
61
minimum allowed value.
L1 Mains Phase voltage higher than
62
maximum allowed value.
L2 Mains Phase voltage lower than
63
minimum allowed value.
"tH0"
Output diodes overtemperature.
(73)
"tH1"
Inverter igbt overtemperature.
(74)
"H2O"
Cooling liquid pressure low.
(75)
"H2O nc"
Cooling unit not connected.
(76)
"GAS LO"
Gas low pressure.
(78)
"GAS HI"
Gas hi pressure.
(79)
"OPn"
Wire Feeder Motor carter open.
(80)
"QC"
Quality Control failure.
(84)
"UPd"
Error during firmware updating.
(85)
"rob"
Emergency stop by Robot, or Robot off.
(90)
"Sti"
Stuck wire.
(91)
"End"
Wire end.
(92)
"Ito"
Inching time out.
(98)
"OFF"
Mains supply missing (Power Source
(99)
power off).
3.300.354
Replace Wire Feeder Motor or Wire Feeder group and/or
motor control board.
Update the Power Source firmware. Replace control
and/or motor control boards and/or Control Panel.
Make sure the mains three phases values. Replace filter
and/or control and/or power boards.
Make sure the mains three phases values. Replace filter
and/or control and/or power boards.
Make sure the mains three phases values. Replace filter
and/or control and/or power boards.
Replace NTC sensor on diode group and/or control board.
Replace NTC sensor on igbt group and/or control board.
Check the wiring between filter board, Q connector on
Power Source rear panel and pressure switch on Cooling
Unit. Replace pressure switch on Cooling Unit and/or
filter and/or control boards.
Check the wiring between filter board, Q connector on
Power Source rear panel. Make sure the presence of a
wired bridge between pin 1 and 2 of the connector of the
Cooling Unit. Replace filter and/or control boards.
Check for the actual gas pressure. Make sure that gas lines
are not clogged where Gas Sensor is connected. Check the
wiring between the Gas Sensor and motor control board.
Replace the motor control board and/or Gas Sensor.
Check for the actual gas pressure. Make sure that gas lines
are not clogged where Gas Sensor is connected. Check the
wiring between the Gas Sensor and motor control board.
Replace the motor control board and/or Gas Sensor.
Replace carter switch and/or Motor Control board.
See the Cebora "Quality Control" option Instruction
Manual.
Repeat the updating sequence or use the Cebora Device
Manager. Replace the control board.
Check Power Source - Robot connections and Robot
power supply and/or plant safety conditions.
Cut the wire or perform the "automatic wire detachment
procedure" (see Robot Interface Instructions Manual).
Replace the wire spool.
Replace control board.
Replace filter and/or control board.
21
GB
15-04-2013