8. Wall Control Installation
SINGLE-POLE INSTALLATION
(One fan controlled by one wall control)
(See Figure 34).
HOT
BLK
NEUTRAL
Figure 34
FAN/LIGHT
WALL CONTROL
BLACK
GROUND
(Continued)
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse or circuit breaker box before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
!
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.