Instruction manual CORSOART
1
2
Tilt support 45°
Open centric
If necessary, the tilt support can be
The centric opens by applying pressure
inserted in the provided place of the
with the index finger on the back of the
lower part of the articulator. Therefore,
locking leverand the upper part can be
the articulator can be placed under
guided to the back without obstruction.
45°.
At the same time, the unlocked lock
prevents slipping out of the upper part
of the articulator.
4
5
Mounting of the
Closed centric
synchronisation system
The condylar ball is fixed in its position
by means of the locking lever.
The locating screw (Art.-No. 12402
and 12403) for the mounting of the
base plateis also located under the
removable plate in the upper-part of
the CORSOART
10
articulators
®
3
Close centric
By applying pressure downward with
the thumb on the front of the locking
lever,the condylar ball will be centered
in the lowest position of the condylar
path. Now is only a rotary movement
with the upper part of the articulator
possible.
®
.

Warning and safety instructions

Inspection of the centric alignment at CORSOART
articulators
®
A lateral play in the upper-part of the articulator can be heard
and is noticeable by a clicking noise.The centric needs to be
adjusted again in order to fix the side shifting.
Please proceed as follows:
– Set the Bennett angle at 10°
– Close the centric-locking lever
– Remove the colored removable disk
General information & care instructions
Precision instruments such as articulators must comply with
the highest requirements. Therefore, the following instruc-
tions for use of these devices should be strictly observed.
– Regular inspection of the axis-ball-system and the condylar
path for contamination. This secures the accurate functiona-
lity of the articulator and maintains the smooth running of
the ball on the axis.
– Contamination that took place here, can be removed by eva-
poration. Subsequently blow dry remaining moisture.
– Under no circumstances may the articulator be put in an ext-
raction unit, pressure pot or ultrasonic bath.
– Use only cleaning agents that are suitable for the cleaning

Legal information

All information in this documentation has been prepared with great careand is subject to changes and mistakes. We assume no
legal responsibility on consequences of incorrect information or improper use.
– Loosen the threaded pin in the stanchion of the upper-part
of the articulator with anAllan wrench
– Centre automatically the anterior tooth guide pit with the
help of the Fix-Clickon the anterior tooth guide plate
– Hold the upper-part of the articulator in position and pull at
the same time the left half-axis outward until it stops. Tigh-
ten the threaded pin with an Allan wrench. Proceed the
same way with the right half-axis.
of light metals and apply according to the manufacturer's
instructions. Cleaning agents, which have a pH value of
below 5 and above 8, may not be used, in order to prevent
damage to the anodised surfaces.
– Please, do not use a plaster dissolution, in order to prevent
damage to the anodised surfaces.
– For cleaning and care, please, use only the special care
spray (Art.-No. 12015).